cor rosion. Slide the r ubber boot o v er the
positi v e ter minal.
9. Install the batter y co v er .
Battery Care
Batter y type is g roup 24.
Important: Bef or e w elding on the machine,
disconnect the ter minal connector fr om the
alter nator to pr ev ent dama ge to the electrical
system.
Note: Chec k the batter y condition w eekly or
after ev er y 50 hours of operation. K ee p the
ter minals and the entire batter y case clean because
a dir ty batter y will disc harg e slo wly . T o clean the
batter y , w ash the entire case with a solution of
baking soda and w ater . Rinse with clear w ater .
Coat the batter y posts and cable connectors with
Grafo 112X (skin-o v er) g rease (T oro P ar t No .
505-47) or petroleum jelly to prev ent cor rosion.
Fuses
T here are 5 fuses in the electrical system. T hey
are located belo w the operators control panel
( Figure 55 and Figure 56 ).
Figure 55
1. Fuses
Figure 56
1. Power outlet
4. Power Take Off (PTO)
2. Seat switch 5. Starter solenoid
3. Ignition switch 6. Light kit
Drive System
Maintenance
Changing the Planetary
Gear Drive Oil
Chang e the oil initially after first 200 hours of
operation. T hereafter c hang e the oil ev er y 800
hours , or yearly , whic hev er occurs first. Use a high
quality SAE 85W -140 g ear lube .
1. With the mac hine on a lev el surface , position
the wheel so that the c hec k/drain plug
( Figure 57 ) is at the lo w est position.
Figure 57
1. Check/drain plug
2. Place a drain pan under the hub , remo v e the
plug, and allo w the oil to drain.