Groundsmaster 4100--D/4110--DPage 5 -- 44Electrical System
Service and Repairs
NOTE: For engine component repair information (e.g.
starter motor), see the Kubota Workshop Manual, Die-
sel Engine, 03--M--E3B Series at the end of Chapter 3
-- Kubota Diesel Engine.
Battery Storage
If the machine will be stored for more than 30 days:
1. Remove the battery and charge it fully (see Battery
Service in this section).
2. Either store battery on a shelf or on the machine.
3. Leavec ablesdisconnectedifthebatteryisstoredon
the machine.
4. Storebatteryinacoolatmospheretoavoidquickde-
terioration of the battery charge.
5. Tohelp preventthebatteryfromfreezing,makesure
it is fully charged (see Battery Service in this section).
Battery Care
1. Battery electrolyte level must be properly main-
tained. The top of the battery must be kept clean. lf the
machine is stored in a location where temperatures are
extremely high, the battery will discharge more rapidly
thanifthemachineisstoredinalocationwheretemper-
atures are cool.
WARNING
Wear safety goggles and rubber gloves when
working with electrolyte. Charge battery in a
well ventilated place so gasses produced
while charging can dissipate. Since the gases
are explosive, keep open flames and electrical
sparks away from the battery; do not smoke.
Nauseamayresultifthegasesareinhaled.Un-
plug charger from electrical outlet before con-
necting or disconnecting charger leads to or
from battery posts.
IMPORTANT: Do not remove fill caps while clean-
ing.
2. Check battery condition weekly or after every 50
hours of operation. Keep terminals and entire battery
casecleanbecauseadirtybatterywilldischargeslowly.
A. Clean batteryby washingentirecasewith asolu-
tionofbakingsodaandwater.Rinsewithclearwater.
B. Coatbatterypostsandcableconnectorswithter-
minal protector (Toro Part No. 107--0392) or petro-
leum jelly to prevent corrosion.
3. Battery cables must be tight on terminals to provide
good electrical contact.
WARNING
Connecting cables to the wrong post could re-
sultinpersonalinjuryand/ordamagetotheelec-
trical system.
4. If corrosion occurs at terminals, disconnect cables.
Always disconnect negative (--) cable first. Clean
clamps and terminals separately. Connect cables with
positive(+)cablefirst.C oatbatterypostsandcablecon-
nectors with terminal protector (Toro Part No.
107--0392) or petroleum jelly to prevent corrosion.
5. Checkelectrolytelevelevery25operatinghoursand
every 30 days if machine is in storage.
6. Maintain celllevelwith distilledwater.Do notfillcells
above the fill line.