T6:PrechargeController(Model04590)
g311532
Figure27
(shownwithhoodremoved)
1.T6:Prechargecontroller
TheeTriFlex3370usesaTEC2401seriesmicrocontrollerasaprecharge
controller(T6)tomanagetheprechargefunction.Prechargeisapreliminary
modewhichlimitstheinrushofcurrentduringthepowerupprocedure.This
current,ifnotlimited,cancauseconsiderablestressordamagetothe48VDC
systemcomponents.Prechargeoccurseachtimethekeyswitchissettothe
ONpositionandlastsforlessthanasecond.Prechargingisimplementedto
increasethelifespanoftheelectroniccomponentsandincreasereliabilityofthe
48VDCsystem.
WhenthekeyswitchissettotheONposition,theT1:primarycontroller
energizesthelogicrelayandpowerissuppliedtotheprechargecontroller
prechargeinput.Theprechargecontrollerthensuppliesacontrolledprecharge
voltagetothereelmotors,liftactuators,andoptional3WDtractionmotorviathe
prechargeoutput.Onceprechargeissuccessful,theT1:primarycontroller
commandstheT6:prechargecontrollerviaaCANmessagetoprovideapathto
groundforthe48VDCmaincontactorcoiltoenergizethemaincontactor(48
VDCpowerbus).RefertoT6:PrechargeController(Model04590)(page5–45)
forT6:prechargecontrollertestinginformation.
Theprechargecontrollercommunicateswiththeothermachinecontrollersona
ControllerAreaNetwork(CAN)bussystem;refertoCANbusCommunications
(page5–12)foradditionalinformation.
Note:Iftheprechargecontroller(T6)isreplacedforanyreason,themachine
softwaremustbeupdated;contactanAuthorizedT oroDistributorforassistance.
Greensmaster®eTriFlex3360and3370
Page5–17
ElectricalSystem:ElectricalSystemOperation
19239SLRevB