75
PERFORMANCE VERIFICATION
Refer to the preceding information in this manual for complete and detailed instructions.
Follow all Safety Instructions.
Gallons Per Acre:
Determine Desired Application Rate From
Manufacturers Labeling ________ G.P.A.
Determine a Vehicle Application Speed _____
M.P.H.
Verify Nozzle Spacing is 20.
Determine Gallons Per Minute
G.P.M. (See
Nozzle Chart on Page 52 & 53) and Use The
Following Formula to verify.
G.P.A. X M.P.H. X 20
5940
x x 20 = = G.P.M.
5940 5940
Select Nozzle Size (See Nozzle Chart on
Page 52 & 53)
based on G.P.M.
Determine Application Pressure
psi
(See Nozzle Chart on Page 52 & 53).
Gallons Per 1,000 sq. ft.:
Determine Desired Application Rate From
Manufacturers Labeling ________ G.P. 1,000 sq. ft.
Determine a Vehicle Application Speed _____
M.P.H.
Verify Nozzle Spacing is 20
Determine Gallons Per Minute
G.P.M. ( See
Nozzle Chart on Page 52 & 53) and Use The
Following Formula to verify
G.P. 1,000 sq. ft. X M.P.H. X 20
136
x x 20 = = G.P.M.
136 136
Select Nozzle Size (See Nozzle Chart on
Page 52 & 53)
based on G.P.M.
Determine Application Pressure
psi
(See Nozzle Chart on Page 52 & 53)
SETUP SPRAY SYSTEM
RATE CHECK
Verify G.P.A. application rate via 1/128th Acre Method
Mark off a test course in a flat area at 204 feet.
Drive the Sprayer with a ½ full tank of water at selected application speed and record the time it takes
to drive 204 feet.
seconds. NOTE: It is important to maintain your application speed during
test.
Fine tune Flowmeter
Set Parking Brake.
Fill tank ½ full with water DO NOT add Chemical at this time.
Install Correct Nozzles.
Turn Pump ON/OFF Switch on.
Turn Master Boom Valve on.
Turn Individual Boom Valves on.
Set engine speed and lock in position.
Program test speed in Spray Pro
.
Set App. Rate to____ GPA.
Visually Inspect The Output Of All Nozzles.
Turn Booms and Pump Off.
Perform Rate Check.