EasyManua.ls Logo

Toro Network VP 4.00 Satellite User Manual

Toro Network VP 4.00 Satellite
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Network VP
TM
4.00 Satellite
User’s Guide
• 16 to 64 stations in eight-station increments
• Field programmable for future upgrades
• Does not require EPROM(s) replacement
• Operates as a stand-alone controller or under
the management of a central computer.
• Supports wireline or radio communications
with the central computer
• Supports hybrid communication (wireline
and radio) for increased flexibility and cost
effectiveness
• 64 irrigation programs:
• Independent stand-alone and central
operation
• Basic, Advanced and Grow-In programs with
unique capabilities to meet your needs
• Multi-Manual, Program Start and Syringe
manual operations
• Operates up to 32 stations simultaneously
• Backwards compatible with Network 8000
Question and Answer IconNeed help?

Do you have a question about the Toro Network VP 4.00 Satellite and is the answer not in the manual?

Toro Network VP 4.00 Satellite Specifications

General IconGeneral
BrandToro
ModelNetwork VP 4.00 Satellite
CategoryController
LanguageEnglish

Summary

Radio Specifications

Fuse & Circuit Breaker Specifications

Satellite Controller Specifications

Introduction

Modes of Operation

Central Mode

Satellite operates under central computer management, allowing program downloads and edits.

Local Mode

Satellite executes downloaded programs; central can edit time/date but not programs.

Off Mode

Satellite executes no watering operations; any current watering terminates.

General Editing

Timing Mechanism Components

Distribution Board Components

Output Board Components

Pump / Common Board Components

Communication Board Components

Power-Up Diagnostics

Home Key

Start Key

Pause / Resume Key

Stop Key

Satellite Settings

Comm Mode

Selects the satellite mode of operation: Central, Local, or Off.

Hold All

Suspends satellite operation and chooses the suspension duration.

Hold Rain

Suspends operation and cancels current watering due to rain.

Reset Prg's

Resets all satellite irrigation programs to their default settings.

Reset Sta's

Resets all station settings to their default values.

Reset Unit

Resets all satellite settings, programs, and configuration values.

Enable Sta's

Resets all disabled stations and clears related alarms.

Reset Amps

Resets electrical current values for all stations.

Station Settings

S01

Selects the station to edit, from Station 01 up to the satellite's maximum station count.

100%

Adjusts station operation percentage, from 0% to 900%.

Sched Today

Displays total scheduled station runtime for the current irrigation day.

Water Today

Displays total station runtime that occurred for the current irrigation day.

Water Yestr

Displays total station runtime that occurred for the previous irrigation day.

Disable

Disables station operation, clearing alarms related to current conditions.

Hold Sta

Delays station operation for a specified duration (01-30 days, Permanent, None).

Is Switch

Assigns station to a switch; master valve/pump won't actuate when switch is active.

Cycles

Adds start times without increasing runtime, dividing runtime by cycle value.

Scheduled Watering

Basic Irrigation Program

Activates stations with one start time daily, specifying duration and simultaneous stations.

Advanced Irrigation Program

Activates stations with up to 24 start times and 2-week calendar scheduling.

Grow-In Irrigation Program

Activates stations for runtime, repeating cycles after specified delay between start/end times.

GMM (Group Multi-Manual)

Activates up to 64 Sequences with 6 stations per sequence, 5-day schedule.

Station Based Flow Management

Utilizes station-based flow management downloaded from SitePro.

Basic Irrigation Program Setting

Advanced Irrigation Program Setting

Grow In Irrigation Program Setting

GMM (Group Multi-Manual) Setting

Manual Watering

Multi-Manual Station Activation Directions

Guides manual station activation for groups of stations with specified runtime and limits.

Syringe

Start Program

% (Percent) Adjust

% Adjust Directions

Provides directions for fine-tuning irrigation programs using percent adjust.

Diagnostics

Menu: Link Monitor

Monitors communication network traffic.

Menu: System Monitor

Monitors all satellites in the system.

Menu: Revision

Displays satellite firmware version and creation date.

Menu: Power-Up Detect

Displays detected stations, sensors, and power-up/down times.

Menu: Seq Stations

Activates all stations sequentially with user-defined time durations.

Menu: Station Test

Tests individual stations by selecting and running them.

Troubleshooting Guide

LED Indicators

Lithium Battery Replacement Procedure

Electromagnetic Compatibility

Related product manuals