ProForce Debris Blower Page 4 11 Electrical System
Fuse
The ProForce Debris Blower uses a 15 amp fuse for cir-
cuit protection. The fuse holder for this fuse is located
next to the engine (Fig. 8).
Testing
1. Make sure that ignition switch is OFF.
2. To prevent unexpected machine operation, discon-
nect the negative battery cable from the battery termi-
nal. Position disconnected negative cable away from
the negative battery terminal.
3. Remove fuse from the fuse holder for testing. Fuse
should have continuity between fuse terminals.
4. After testing, install fuse into fuse holder.
5. Connect negative battery cable to negative battery
terminal. Tighten nut that secures battery cable from 10
to 15 ftlb (14 to 20 Nm). Make sure that battery cover
is secured.
1. Wire harness
2. Fuse
3. Fuse cover
Figure 8