Reelmaster 6500D/6700–D
Page 4 73
Hydraulic System
18. Remove the two alignment pins that align the port
manifold, valve ring and isolation manifold (Fig. 56).
19. Remove the isolation manifold (four plates bonded
together) (Fig. 57).
20. Inspect the ground surfaces of the isolation man-
ifold. You should notice a normal polished pattern due
to the rotation of the valve plate, and on the opposite
side a normal polished pattern due to the action of the
commutator cover and commutator seal. The holes and
edges should be free of nicks. The manifold surfaces
should be free of nicks or scoring. If the manifold has de-
veloped any of these conditions, it must be replaced.
21. Remove the two isolation manifoldmetering ring
alignment pins (Fig. 58).
Figure 56
Figure 57
Figure 58