Servicing the Air Cleaner (continued)
G424758
6. If a red band displays in the service indicator,
press the reset button at the end of the
indicator.
7. Close and latch the hood.
Fuel System Maintenance
Inspecting the Fuel Lines and Connections
1. Prepare the machine for maintenance.
2. Open the hood.
3. Inspect the fuel lines for wear, deterioration, damage, or loose fittings.
Note: Repair or replace any worn or damaged fuel lines; tighten any loose fittings.
4. Close and latch the hood.
Draining the Fuel/Water Separator
1. Prepare the machine for maintenance.
2. Drain the water separator as shown.
Maintenance: Fuel System Maintenance Page 6–20 3466-702 A