EasyManua.ls Logo

Toro Titan MX6000 - Fuel and Electrical System Maintenance

Toro Titan MX6000
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
InstallingtheSparkPlug
Tightenthesparkplugto27N-m(20ft-lb).
B
A
20 ft-lb
27 N-m
g028109
C
D
Figure42
CleaningtheBlowerHousing
Every100hours/Yearly(whichevercomesrst)
Toensurepropercooling,makesurethegrassscreen,cooling
ns,andotherexternalsurfacesoftheenginearekeptclean
atalltimes.
Annually,orevery100hoursofoperation(moreoften
underextremelydusty,dirtyconditions),removetheblower
housing,andanyothercoolingshrouds.Cleanthecooling
nsandexternalsurfacesasnecessary.Makesurethecooling
shroudsareinstalled.
Important:Operatingtheenginewithablockedgrass
screen,dirtyorpluggedcoolingns,and/orcooling
shroudsremoved,willcauseenginedamagedueto
overheating.
FuelSystem
Maintenance
DANGER
Incertainconditions,gasolineisextremely
ammableandhighlyexplosive.Areorexplosion
fromgasolinecanburnyouandothersandcan
damageproperty.
Performanyfuelrelatedmaintenancewhenthe
engineiscold.Dothisoutdoorsinanopenarea.
Wipeupanygasolinethatspills.
Neversmokewhendraininggasoline,andstay
awayfromanopenameorwhereasparkmay
ignitethegasolinefumes.
ReplacingtheFuelFilter
ServiceInterval:Every100hours/Yearly(whichevercomes
rst)(moreoftenunderdusty,dirty
conditions).
1.Disengagetheblade-controlswitch(PTO),movethe
motion-controlleverstotheneutral-lockposition,and
settheparkingbrake.
2.Stoptheengine,removethekey,andwaitforallmoving
partstostopbeforeleavingtheoperatingposition.
34

Table of Contents