Registering from TopAccess 243
Master Password
Enter a password for changing the Encrypt PDF setting.
yThe user password is set “12345” at our factory. Ask the administrator for resetting master
password.
yThe passwords must be entered in one-byte alphanumeric characters. The minimum and
maximum numbers of characters allowed are 1 and 32.
yThe user password must differ from the master password.
yThese passwords can be re-entered only by an authorized user. Users cannot change the
settings of the Encryption Level field and the Authority field noted below if they are not
authorized to change the master password. Ask the administrator for resetting these
passwords.
yFor the details of the encryption setting, see the User Functions Guide.
Encryption Level
Select the desired encryption level.
- 128-bit RC4 - Select this to set an encryption level to the one compatible with Acrobat
5.0, PDF V1.4.
40-bit RC4Select this to set an encryption level to the one compatible with Acrobat
3.0, PDF V1.1.
Authority
Check the desired types of authority for Encrypt PDF.
- Printing
- Change of Documents
- Content Copying or Extraction
- Content Extraction for accessibility
7) File Name
The file name will be “(From Name)-NNN”. The file name cannot be changed.
8) Fragment Message Size
Select the size of the message fragmentation.