© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 83
2
931 Image Density
adjustment
Fine adjust-
ment of “man-
ual density”/
Center value
Custom
Mode 1
PPC 128
<0-255>
SYS When the value
increases, the image of
the center step becomes
darker.
1
932 Custom
Mode 2
PPC 128
<0-255>
SYS 1
933 Custom
Mode 3
PPC 128
<0-255>
SYS 1
934 Image Density
adjustment
Fine adjust-
ment of “man-
ual density”/
Light step
value
Custom
Mode 1
PPC 20
<0-255>
SYS When the value
increases, the image of
the “light” step density
becomes lighter.
1
935 Custom
Mode 2
PPC 20
<0-255>
SYS 1
936 Custom
Mode 3
PPC 20
<0-255>
SYS 1
937 Image Density
adjustment
Fine adjust-
ment of “man-
ual density”/
Dark step
value
Custom
Mode 1
PPC 20
<0-255>
SYS When the value
increases, the image of
the “dark” step density
becomes darker.
1
938 Custom
Mode 2
PPC 20
<0-255>
SYS 1
939 Custom
Mode 3
PPC 20
<0-255>
SYS 1
940 Image Density
adjustment
Fine adjust-
ment of “auto-
matic density”
Custom
Mode 1
PPC 128
<0-255>
SYS When the value
increases, the image
becomes darker.
1
941 Custom
Mode 2
PPC 128
<0-255>
SYS 1
942 Custom
Mode 3
PPC 128
<0-255>
SYS 1
943 Image Gamma data
slope adjust-
ment
Custom
Mode 1
PPC 0
<0-99>
SYS One’s place:
0: Equivalent to the set
value 5
1 to 9: Select the slope of
Gamma curve (The
larger the value is, the
larger the slope
becomes.)
Ten’s place:
0: Equivalent to the set
value 5
1 to 9: Select the slope of
low density (The smaller
the value is, the darker
the background
becomes.)
00: Use default value
1
944 Custom
Mode 2
PPC 0
<0-99>
SYS 1
945 Custom
Mode 3
PPC 0
<0-99>
SYS 1
976 Mainte-
nance
Equipment number (serial
number) entry
ALL - SYS When this adjustment is
performed with this code,
the setting code (08-995)
is also performed auto-
matically (10 digits).
1
Adjustment mode (05) <e-STUDIO202L/203L/232/233/282/283>
Code
Classi-
fication
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Proce-
dure
07/11