e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283 © 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 90
253 Mainte-
nance
Error history display ALL - SYS Displaying of the latest
20 errors data
2
254 Paper
feeding
LT <-> A4/LD <-> A3 PRT 0
<0-1>
SYS Sets whether the data is
printed on the different
but similar size paper or
not when the paper of
corresponding size is
not available.
0: Valid (The data is
printed on A4/A3
when LT/LD is
selected or vice
versa.)
1: Invalid (The mes-
sage to use the
selected paper size
is displayed.)
1
255 Paper
feeding
PFP/LCF installation ALL 0
<0-4>
M 0: Automatic
1: PFP single-drawer
type installed
2: PFP dual-drawer
type installed
3: LCF installed
4: Not installed
1
256 Paper
feeding
Paper size setting /LCF ALL EUR: A4
UC: LT
JPN: A4
M Press the button on the
LCD to select the size.
9
257 Counter Counter copy ALL -
<1-2>
- 1) Electrical counter →
Backup counter
2) Backup counter →
Electrical counter
(P. 2-151 "Fig. 2-4")
-
258 Mainte-
nance
FSMS acceptance ALL 1
<0-2>
SYS Sets whether the FSMS
connection is accepted
or not.
0: Prohibited
1: Accepted (USB nor-
mal connection)
2: Accepted (USB
forcible connection)
1
259 Network Storage period trial and pri-
vate
PRT 14
<0-30>
SYS 0: No limits
1 to 30: 1 to 30 days
1
260 Network Web data retention period SCN 10
<3 digits>
SYS When a certain period
of time has passed
without operation after
accessing TopAccess,
the data being regis-
tered is automatically
reset. This period is set
at this code.
(Unit: Minute)
1
263 User
interface
Administrator's password
(Maximum 10 digits)
ALL 123456
<10
digits>
- The password can be
entered in alphabets
and figures (A-Z, a-z, 0-
9) within 10 digits.
11
264 Network File retention period SCN 30
<0-999>
SYS 0: No limits
1 to 999: 1 to 999 days
1
Setting mode (08) <e-STUDIO200L/230/230L/280>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Proce-
dure