e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283 © 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 2
(4) After about two minutes, the value B automatically starts changing.
Fig. 3-3
(5) After a short time, the value B becomes stable and the display changes as follows.
Fig. 3-4
(6) Check if the value B is within the range of 235 to 245 (the output voltage range of the auto-toner
sensor is 2.35 V to 2.45 V).
(7) If the value B is not within the range of 235 to 245, press the Up or Down button to adjust the
value manually.
The relation between the button and the values A and B is as follows.
(8) Press the [ENTER] or [INTERRUPT] button.
The drum, developer unit, etc. are stopped and the following is displayed.
Fig. 3-5
(9) Turn the power OFF.
(10) Install the toner cartridge.
Button to be pressed Value A Value B
Up Increased Increased
Down Decreased Decreased