© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
ADJUSTMENT
3 - 61
3
(2) Step 2
Case C:
Loosen the fixing screw and hand screw of the right side hinge and then turn the adjustment
screw counterclockwise.
Case D:
Loosen the fixing screw and hand screw of the right side hinge and then turn the adjustment
screw clockwise.
When adjusting, refer to the hinge position (scribed line) and be sure not to move it from the
hinge position ±0.5 mm or further. Otherwise, image failures such as a jitter may occur.
(3) Step 3
Case E:
Adjust the reverse aligning adjustment position to the rear side “-” of the original ( P. 3 - 6 4
"3.10.6 Adjustment of aligning at reversing").
Case F:
Adjust the reverse aligning adjustment position to the rear side “+” of the original ( P.3-64
"3.10.6 Adjustment of aligning at reversing").
Fig. 3-68
Fig. 3-66 Fig. 3-67