© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
TROUBLESHOOTING
5 - 113
5
18)Image dislocation in feeding direction
Fig. 5-18
Defective area Step Check items Prescription
Scanner/Printer adjust-
ment
1 Have the printed images been dislo-
cated in the same manner?
Adjust the position of the leading
edge of paper in the Adjustment
Mode.
Registration roller 2 Is the registration roller dirty, or the
spring detached?
Clean the registration roller with alco-
hol.
Securely attach the springs.
3 Is the registration roller working prop-
erly?
Adjust or replace the gears if they are
not engaged properly.
Feed clutch 4 Is the feed clutch working properly? Check the circuit or feed clutch, and
replace them if necessary.
Pre-registration guide 5 Is the pre-registration guide installed
properly?
Install the guide properly.