© 2004 - 2007 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO200L/202L/203L/230/232/233/280/282/283
ADJUSTMENT
3 - 59
3
3.10.3 Adjustment of skew
When an image skew occurs, adjust it according to the following steps, Step 1 Step 2 Step 3.
Note: Note:
Perform this adjustment after confirming that the equipment has been adjusted properly.
Prior to this adjustment, of RADF position and height are needed to be adjusted.
(1) Step 1
Case A:
Adjust the aligning adjustment position to the rear side “-” of the original ( P.3-62 "3.10.5
Adjustment of aligning").
Case B:
Adjust the aligning adjustment position to the rear side “+” of the original ( P.3-62 "3.10.5
Adjustment of aligning").
Fig. 3-65
AB
Paper
Original
White arrow: feeding direction