© 2004 - 2007 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO200L/202L/203L/230/232/233/280/282/283
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 7
2
2.1.2 Service call
Error code Classification Contents Troubleshooting
C010 Drive system
related service call
Main motor abnormality: The main motor is not rotating
normally.
P. 5-47
C040 Paper feeding sys-
tem related ser-
vice call
PFP motor abnormality: The PFP motor is not rotating
normally.
P. 5-48
C130 Upper drawer tray abnormality: The upper drawer tray
motor is not rotating or the upper drawer tray is not mov-
ing normally.
P. 5-49
C140 Lower drawer tray abnormality: The lower drawer tray
motor is not rotating or the lower drawer tray is not mov-
ing normally.
P. 5-49
C150 PFP upper drawer tray abnormality: The PFP upper
drawer tray motor is not rotating or the PFP upper drawer
tray is not moving normally.
P. 5-50
C160 PFP lower drawer tray abnormality: The PFP lower
drawer tray motor is not rotating or the PFP lower drawer
tray is not moving normally.
P. 5-50
C180 LCF tray-up motor abnormality: The LCF tray-up motor is
not rotating or the LCF tray is not moving normally.
P. 5-51
C1A0 LCF end fence motor abnormality: The LCF end fence
motor is not rotating or the LCF end fence is not moving
normally.
P. 5-52
C1B0 LCF transport motor abnormality: The LCF transport
motor is not rotating normally.
P. 5-53
C260 Scanning system
related service call
Peak detection error: Lighting of the exposure lamp
(white reference) is not detected when power is turned
ON.
P. 5-54
C270 Carriage home position sensor not turning OFF within a
specified period of time: The carriage does not shift from
its home position in a specified period of time.
P. 5-55
C280 Carriage home position sensor not turning ON within a
specified period of time: The carriage does not reach to
its home position in a specified period of time.
P. 5-55
C410 Fuser unit related
service call
Thermistor or heater abnormality at power-ON: Abnor-
mality of service call the thermistor is detected when
power is turned ON or the temperature of the fuser roller
does not rise in a specified period of time after power is
turned ON.
P. 5-56
C430 Thermistor abnormality after abnormality judgment:
Abnormality of the thermistor is detected after a specified
period of time has passed from power-ON (including
ready state).
P. 5-57
C440 Heater abnormality after abnormality judgment: The tem-
perature of the fuser roller has exceeded the range of
control (in this case, the main switch turns OFF automati-
cally) or does not even reach the range.
P. 5-57
C450 Thermistor abnormality during printing: Abnormality of the
thermistor is detected during printing.
P. 5-57
C550
(C780)
Optional communi-
cation related ser-
vice call
RADF I/F error: Communication error has occurred
between the RADF and the scanner.
P. 5-58
C570 Communication error between Engine-CPU and IPC
board
P. 5-58
C580 Communication error between IPC board and finisher P. 5-58
07/04