© 2004 - 2007 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO200L/202L/203L/230/232/233/280/282/283
ADJUSTMENT
3 - 65
3
(4) Fix the plate spring temporarily with the
screw on the left. Then press the plate spring
slightly in the direction of an arrow and
tighten the screw in the position where the
gap (D) between the plunger and the flapper
lever is eliminated.
Fig. 3-74
D
D
Flapper lever
Plunger