DRUM RELATED SECTION
11 - 12
[F] Main charger cleaner
[G] Needle electrode
(1) Take off the main charger
( P.11-11 "[D] Main charger").
(2) Release the hook of the cleaning shaft. Then
rotate the shaft at 90 degrees to take it off.
Fig. 11-15
(1) Take off the main charger grid and main
charger cleaner
( P.11-11 "[E] Main charger grid",
P.11-12 "[F] Main charger cleaner").
(2) Take off the terminal covers of both front and
rear sides.
Fig. 11-16
(3) Remove the terminal and spring. Then take
off the needle electrode.
Notes:
1. Do not touch the needle electrode directly
with bare hands.
2. Make sure not to hold or bend the needle
electrode.
Fig. 11-17
Main charger cleaner
Terminal cover
Needle electrode
Terminal