PRINTING FROM UNIX/Linux
- 72 -
2
1
3
4
5
6
7
Printing Modes
The printing mode can be selected using the following options.
If this option is not specified, the printer’s default value will be
used.
A private printing job requires the user to enter a maximum
number of 63 character long string.
Character lengths longer than 63 will be clipped to 63.
The following characters are invalid, but no type checking is
carried out.
” & ’ ( ) ; < > ˆ ` | ~ @ # % * !
Department Code
The department code can be set using the following option.
A department code is specified within 63 characters.
If the entered department code is longer than 63 characters, it
is clipped to 63 characters when a job is sent.
The following characters are invalid for department codes:
" & ' ( ) ; < > ^ ` | ~ @ # % * !
Memo
How the equipment performs printing for an invalid
department code print job, for which an invalid department
code is specified, varies depending on the Invalid
Department Code Print Job setting that can be set in the
TopAccess Administrator mode and whether SNMP
communication is enabled or not.
- When SNMP communication is enabled and Invalid
Department Code Print Job is set to [Store to invalid job
list], an error message will be displayed when an invalid
department code is entered.
- When SNMP communication is disabled and Invalid
Department Code Print Job is set to [Store to invalid job
list], the invalid department code print job will be stored
in the invalid department code print job list without
printing.
- When the Invalid Department Code Print Job is set to
[Print], the invalid department code print job will be
printed.
- When the Invalid Department Code Print Job is set to
[Delete], the invalid department code print job will be
deleted.
For the appropriate department code, ask your system
administrator.
Distinguish Thin Lines
This sets whether to distinguish thin lines or not. This mode
can be set using the following option.
Example: The command to set the thin line limit mode is “lp -o
thinlinelimit=on <filename>”.
Do Not Print Blank Pages
This sets whether or not a blank page is printed. This mode
can be selected using the following option.
Example: The command to set the blank page mode is “lp -o
blankpage=0 <filename>”.
Toner Save
The toner save mode can be set using the following option.
Example: The command to set the toner save mode is “lp -o
tonersave=on <filename>”.
Booklet Modes
The booklet mode can be selected using the following options.
Note
The booklet mode applies only for the PostScript data.
Performing the booklet printing using the PCL data is
invalid.
Option Value Alternate Value Description
normal Process as a normal print
job.
hold Process as a hold print
job.
proof Process as a proof print
job.
private=din Process as a private print
job. The din is up to a 63-
digit (between 1 to 63)
password.
Option Value Alternate Value Description
dept=code Set the department code.
A department code within
63 characters comes in
[code].
Option Value Alternate Value Description
thinlinelimit=on ON Set the thin line limit
mode.
thinlinelimit=off OFF Cancel the thin line limit
mode.
Option Value Alternate Value Description
blankpage=0 Set the blank page mode
(disable Do not Print Blank
Pages).
blankpage=1 Cancel the blank page
mode (enable Do not Print
Blank Pages).
Option Value Alternate Value Description
tonersave=on ON Set the toner save mode.
tonersave=off OFF Cancel the toner save
mode.
Option Value Alternate Value Description
booklet=letter lt
LT
Select Letter size paper
for the booklet printing
mode.
booklet=A4 a4 Select A4 size paper for
the booklet printing mode.