EasyManua.ls Logo

Toshiba e-STUDIO353 - Page 292

Toshiba e-STUDIO353
764 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
e-STUDIO350/352/353/450/452/453 © 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 4
[Procedure to key in adjustment values]
In accordance with the procedure described below, make adjustment of each adjustment item so that
the measured values obtained from test copies satisfy the specification. By pressing the [FAX] button,
immediately after starting the Adjustment Mode (05S), single-sided test copying can be performed (nor-
mal copy mode).
0
1
5
POWER
ENTER
INTERRUPT
FAX
Digital keys
START
: Enter codes.
<Operation keys> <Display>
Varies with the code “XXX” keyed in
Current adjustment
value
Adjustment value newly entered
(If no entering, YYY is displayed.)
Power OFF/ON
: Exit the Adjustment Mode.
: Test copy
Digital keys : Enter adjustment
values.
Value ZZZ is stored
replacing values YYY.
If the test copy does not
satisfy the specified values,
return to step 1 and
repeat the adjustment
procedure.
or
( CLEAR Use to make corrections)
100% AA3
TEST MODE
100% AA3
TEST MODE
100% AA3
Wait Warming Up
100% AA3
COPYING
Code No.
100%
YYY ZZZ
XXX A3
TEST MODE
04/05

Table of Contents