ADJUSTMENT
3 - 40
3.7 Adjustment of the Scanner Section
3.7.1 Carriages
[A] Installing carriage wires
When replacing the carriage wires, refer illustrations below:
[Front side]
Fig. 3-32
[Rear side]
Fig. 3-33
Adjustment of the carriage wire tension is not necessary since a certain tension is applied to the car-
riage wires by the tension springs.
Note: Note:
Make sure the tension applied to the wire is normal.
Wire pulley
Tension spring
Bracket for carriage-1
Carriage wire
Carriage-2
Idler pulley
Hook
Idler pulley
Carriage-2
Carriage wire
Bracket for carriage-1
Hook
Tension spring
Wire pulley