[E] Image position adjustment of the secondary scanning direction
(1) While pressing [0] and [5] simultaneously, turn the power ON (Adjustment Mode)
(2) Place a ruler on the original glass with its leading edge pushed against the original scale on the
left.
(3) Press [FAX] to make a copy at the mode of A3 (LD), 400% and lower drawer.
(4) Measure the distance D from the leading edge of the paper to 10 mm of the copied image of the
ruler.
(5) Check if the distance D is within the range of 34±0.5 mm.
(6) If not, use the following procedure to change values and repeat the steps 3. to 5. above.
<Procedure>
(Adjustment Mode) (Key in the code [305] with the digital keys) [START]
(Key in a value (acceptable values: 0 to 255))
Press the [ENTER] or the [INTERRUPT] button (stored in memory).
(“100% A” is displayed.)
* The larger the adjustment value, the more the image is shifted to the trailing edge (0.68 mm/
step).
Fig. 3-9
10 20 30 40
D
Feeding direction