ADJUSTMENT
3 - 84
(6) Loosen the screw on the home position sensor plate at the front.
Fig. 3-117
(7) Adjust the position of the front jogging plate home position sensor (S6) with reference to the
index.
EX. 1
If the width is 319 mm in step (4), the difference from the standard is +2 mm, it requires relocation
of the sensor [3] in the direction of arrow A by 2 mm.
EX. 2If the width is 316 mm in step (4), the difference from the standard is -1 mm; it requires relo-
cation of the sensor [3] in the direction of arrow B by 1 mm.
Fig. 3-118
Screw
Home position
sensor plate
AB