© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO350/352/353/450/452/453
TROUBLESHOOTING
5 - 113
5
5) Blurred image
Defective area Step Check items Prescription
Paper 1 Is the paper in the drawer or LCF
damp?
Change paper. Avoid storing paper in
damp place.
Bedewed scanner 2 Is the scanner bedewed? Clean it.
Drum 3 Is the drum surface wet or dirty? Wipe the drum with a piece of dry cloth.
* Do not use alcohol or other organic sol-
vents.
Ozone exhaust 4 Is the ozone exhaust fan operating
properly?
Check the connection of connector.
Replace the ozone exhaust fan.
5 Is the ozone filter stained or dam-
aged?
Replace it.
Feeding direction
04/09