–20–
Hydro Unit
Installation Manual
EN
Control line
Fig. 7-19
Fig. 7-20
TB07
A
B
C
D
1
2
3
4
5
6
A
B
1
2
3
4
1
2
3
4
1
2
3
4
TB05
PJ20
PJ20
TB06
CN208
OPTION OPTION
CN209
1
2
7
8
9
1
2
3
4
TB04
CW
CCW
N
Mixing-Valve
type 2 for 2 zone
control
Max 12 m
230 V 100 mA
0.75 mm² or more
Mixing-Valve type 1
for 2 zone control
Max 5 m shielded wire
0.75 mm² or more
Temp sensor in hot
water cylinder
Max 12 m
230 V 1 A
0.75 mm² or more
Pump (local)
Max 12 m
230 V 100 mA
0.75 mm² or more
Booster heater
(local)
Max 12 m
230 V 1 A
0.75 mm² or more
Alert output
(local)
Boiler operation
(local)
Defrost output
(local)
Compressor
operation output
(local)
Max 12 m non
voltage 0.75 mm² or
more
Temp sensor for
2 zone control
Max 5 m shielded
wire 0.75 mm² or
more
2Way-Valve for
cooling stop
3Way-Valve for hot
water cylinder
Max 50 m
0.50 mm² or more
2nd remote controller
6B6A 6D
6C
TF1
TB 06
11 12
13
TB 01
Don't apply
220-240V
or
breakdown
will occur.
TTW
31 32
L
TB 03
HOT WATER CYLINDER
L
TB 02
N
1
3
2
L2L1
L3
N
WPM
51
TB 05
52
41
MIXV
53
54
55
56
57
58
59
2WV
BH
3WV
42
43
44
TB 04
N
L3
L1 L2
N
TB03
TB01
TB02
Input power
380-400 V 3N
~ 50 Hz
Input power
220-230 V ~
50 Hz
Input power
220-230 V ~
50 Hz
Hot
water
cylinder
to Outdoor unit
Hot water cylinder
power supply
Outdoor unit
connection
Sensor
connection
Backup heater
power supply
20-EN