Refrigerant Pipe Lengths and Height
The length and height of the refrigeration pipe must be within the following values.
As long as the Hydro Unit is installed within these ranges, no additional refrigerant is required.
Minimum Pipe Length
HWS-803H-E : 5 m
HWS-1103H**-E : 5 m
HWS-1403H**-E : 5 m
HWS-1603H**-E: 5m
Maximum Pipe Length and Height
H: Max. ±30 m (above or below)
L: Max. 30 m
Note
The maximum pipe length cannot be increased using additional
refrigerant.
Refrigeration and Water Cycle Diagrams
Outdoor Unit: HWS-803H-E
Hydro Units:
HWS-803XWH**-E
Outdoor Units: HWS-1103H**-E, HWS-1403H**-E
Hydro Units:
HWS-1403XWH**-E