10Hydro unit and Outdoor Unit Settings
Hydro unit
1. Hydro unit Setting
1-1. Setting switch names and positions
1-2. SW02 (System switching 1)
1-3. SW10 (Pump switching)
1-4. SW11 (Heater Yes/No switching)
1-5. SW12 (System switching 2)
1-6. SW13 (System switching 3)
SW02 Switching details Factory setting Remarks
02_1 OFF
02_2 OFF
02_3 OFF
02_4 Room thermostat No OFF
SW10 Switching details Factory setting Remarks
10_1 OFF
10_2 OFF
10_3 Enhanced pump2 Interlock Yes/No Yes OFF
10_4 OFF
SW11 Switching details Factory setting Remarks
11_1 Internal backup heater Energized Yes/No Energized OFF
11_2 Hot water cylinder heater Energized Yes/No Energized OFF
11_3 Booster heater Energized Yes/No Energized OFF
11_4 OFF
SW12 Switching details Factory setting Remarks
12_1 Hot water supply Yes OFF
12_2 ZONE1 Yes OFF
12_3 ZONE2 No OFF
12_4 OFF
SW13 Switching details Factory setting Remarks
13_1 3WV SPST/SPSD Specification switching SPST OFF
13_2 Boiler placement No OFF
13_3 Auto Restart of power outage Yes OFF
13_4 OFF
SW10
SW01
SW02
SW11
SW12 SW13
SW07
+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 105 Monday, October 5, 2009 2:09 PM