EasyManua.ls Logo

Toshiba HWS-802XWHM3-E - 6 Key Electric Component Rating; 6-1.Hydro Unit

Toshiba HWS-802XWHM3-E
168 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
Toshiba
6 Key Electric Component Rating
6-1. Hydro Unit
HWS-802XWHM3-E, 802XWHT6-E
O ·········Applied
OP······· Optional accessory
No. Component name
Model name
Type name Rating
M3-E T6-E
1
Circulating pump
OO
UPS025-65 K 130 AC230 V 0.54 A (MAX)
2
Backup heater 6 kW
OO
AC 400 V (3N) 6 kW (AC230 V 3 kW
compatible)
3
Backup heater 9 kW
AC400V (3N) 9 kW
4
Water heat exchange
temperature sensor
(TC sensor)
OO
10 kΩ (25°C)
5
Water inlet temperature sensor
(TWI sensor)
OO
10 kΩ (25°C)
6
Water outlet temperature sensor
(TWO sensor)
OO
10 kΩ (25°C)
7
Heater outlet water temperature
sensor
(THO sensor)
OO
10 kΩ (25°C)
8
Floor inlet temperature sensor
(TFI sensor)
OO
10 kΩ (25°C)
9
Pressure switch
OO
Operating pressure 4.15 MPa +0 -0.3 MPa
10
Low pressure sensor
OO
Operating pressure 0.20 MPa
11
Bimetal thermostat (auto)
OO
Operating temperature 75±3°C DC42 V / 0.2 A
12
Bimetal thermostat (single
operation)
OO
Operating temperature 95±5°C AC250 V / 16 A
13
Flow switch
OO
Operating flowing quantity 13 L/min
14
Output board (OP)
OP OP
TCB-PCIN3E AC230 V 0.5 A DC24 V 1 A
15
Input board (OP)
OP OP
TCB-PCM03E Contact input
16
Remote control
OO
HWS-AMS11E
17
Water 3-way valve terminal
OO
AC230 V 0.1 A
2Wire, 3Wire SPST, SPDT type mountable
18
Water 2-way valve terminal
OO
AC230 V 0.1 A 2Wire type mountable
19
Mixing valve terminal
OO
AC230 V 0.1 A
3Wire SPST, SPDT type mountable
20
Circulating pump terminal
OO
AC230 V 1.0 A
21
Booster heater terminal
OO
AC230 V 1.0 A
22
Fuse
OO
AC 250 V 30 A