25
Toshiba
HWS-1402XWHM3-E, 1402XWHT6-E, 1402XWHT9-E
O ·········Applied
OP······· Optional accessory
No. Component name
Model name
Type name Rating
M3-E T6-E T9-E
1
Circulating pump
OOO
UPS25-80 130 AC230 V 0.83 A (MAX)
2
Backup heater 6 kW
OO
AC 400 V (3N) 6 kW (AC230 V 3kW compatible)
3
Backup heater 9 kW
O–
AC 400 V (3N) 9 kW
4
Water heat exchange
temperature sensor
(TC sensor)
OOO
10 kΩ (25°C)
5
Water inlet temperature sensor
(TWI sensor)
OOO
10 kΩ (25°C)
6
Water outlet temperature sensor
(TWO sensor)
OOO
10 kΩ (25°C)
7
Heater outlet water temperature
sensor
(THO sensor)
OOO
10 kΩ (25°C)
8
Floor inlet temperature sensor
(TFI sensor)
OOO
10 kΩ (25°C)
9
Pressure switch
OOO
Operating pressure 4.15 MPa +0 -0.3 MPa
10
Low pressure sensor
OOO
Operating pressure 0.20 MPa
11
Thermal protector (auto)
OOO
Operating temperature 75±3°C DC42 V / 0.2 A
12
Thermal protector (single
operation)
OOO
Operating temperature 95±5°C AC250 V 16 A
13
Flow switch
OOO
Operating flowing quantity 18 L/min
14
Output board (OP)
OP OP OP
TCB-PCIN3E AC230 V 0.5 A DC24 V 1 A
15
Input board (OP)
OP OP OP
TCB-PCM03E Contact input
16
Remote control
OOO
HWS-AMS11E
17
Water 3-way valve terminal
OOO
AC230 V 0.1 A
2Wire, 3Wire SPST, SPDT type mountable
18
Water 2-way valve terminal
OOO
AC230 V 0.1 A 2Wire type mountable
19
Mixing valve terminal
OOO
AC230 V 0.1 A
3Wire SPST, SPDT type mountable
20
Circulating pump terminal
OOO
AC230 V 1.0 A
21
Booster heater terminal
OOO
AC230 V 1.0 A
22
Fuse
OOO
AC 250 V 30 A
+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 25 Monday, October 5, 2009 2:09 PM