EasyManua.ls Logo

Toshiba MMY-MAP0724FT9UT - User Manual

Toshiba MMY-MAP0724FT9UT
19 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
For commercial use
Not accessible to the general public
Vente interdite au grand public
Kein öffentlicher Zugang
Non accessibile a clienti generici
No destinado al público en general
Não acessível ao público em geral
Niet geschikt voor huishoudelijk gebruik
Μη προσβάσιμο από το γενικό κοινό
Недоступен для посторонних
Genel erişime açık değildir
AIR CONDITIONER (MULTI TYPE)
Outdoor Unit
Model name:
<Heat Recovery Model>
MMY-MAP0724FT9UL
MMY-MAP0964FT9UL
MMY-MAP1204FT9UL
MMY-MAP0724FT6UL
MMY-MAP0964FT6UL
MMY-MAP1204FT6UL
Owner’s Manual
For OUTDOOR USE only
Pour une UTILISATION EN EXTÉRIEUR
uniquement
Manuel du propriétaire 18
Français
Owner’s Manual 1
English
+00EH99943901_00Ta.book Page 1 Thursday, May 23, 2013 7:17 PM

Questions and Answers

  • R
    ryangibsonAug 10, 2025
    Why is my Toshiba Air Conditioner not cooling or warming sufficiently?
    • D
      Dr. Dustin ColemanAug 10, 2025
      Several factors can cause insufficient cooling or warming. Check if the air intake or discharge of the outdoor unit is obstructed, and ensure all doors and windows are closed. Clean the air filter if it's clogged with dust, and adjust the discharge louver to the appropriate position. Also, verify that the air selection is not set to “LOW” or “MED”, and the operation mode is not set to “FAN”. Adjust the setup temperature, and check if the outdoor temperature is within the operational range.
  • A
    Alejandro HolderAug 15, 2025
    What to do if my Toshiba MMY-MAP0724FT9UT does not operate?
    • M
      Mark StephensAug 15, 2025
      If your Toshiba Air Conditioner isn't operating, first check the power supply and ensure the power switch is turned on. Inspect the power fuse or circuit breaker. If a protective device has operated, address the issue that triggered it. Also, check if the timer is set. Finally, verify the outdoor temperature is within the operational range.
  • C
    Clayton PinedaAug 20, 2025
    What to do if the switch operation does not work properly on my Toshiba MMY-MAP0724FT9UT?
    • W
      William RodriguezAug 20, 2025
      If the switch operation does not work properly, turn off the main power supply switch and immediately contact the dealer.
  • J
    John RogersAug 25, 2025
    Why does my Toshiba Air Conditioner operate or stop automatically?
    • B
      barbarahernandezAug 26, 2025
      If your Toshiba Air Conditioner operates or stops automatically, the timer settings may be the cause. Check the timer “ON” or “OFF” settings to ensure they are correctly configured.
  • E
    Elizabeth RamirezAug 30, 2025
    What to do if the main power fuse often blows out in my Toshiba Air Conditioner?
    • K
      Kimberly OsborneAug 30, 2025
      If the main power fuse often blows out, or the circuit breaker is often activated, turn off the main power supply switch and immediately contact the dealer.
  • B
    Beth GonzalesSep 3, 2025
    What to do if my Toshiba MMY-MAP0724FT9UT does not operate even after removing the cause of the protective device activation?
    • K
      Kelly LynchSep 3, 2025
      If the air conditioner does not operate even after the cause of the protective device activation has been removed, turn off the main power supply switch and immediately contact the dealer.

Toshiba MMY-MAP0724FT9UT Specifications

General IconGeneral
Heating Capacity8.0 kW
Power Supply220-240 V
RefrigerantR410A
PhaseSingle
Operating Temperature (Heating)-15 to 24 °C

Related product manuals