Information pertaining to the SMMS-i outdoor unit.
Wiring diagrams for the outdoor unit.
Wiring diagrams for various types of indoor units.
Safety warnings related to the R410A refrigerant.
Cautions for installation and service procedures.
Parts rating and specifications for outdoor units.
Parts rating and specifications for various indoor units.
Visual layout and identification of parts in the outdoor unit.
Details on normal cooling and heating operations under various conditions.
Procedures for emergency operation scenarios.
Control outlines and specifications for the indoor unit.
Details on applied control functions and circuit configurations.
Block diagram of the indoor controller.
Specific applied control functions for outdoor units.
Procedure to check indoor unit operation independently.
Procedure for setting indoor unit function DN codes when the system is at rest.
Function to adjust outdoor fan speed for high static pressure applications.
Settings to establish priority for cooling or heating modes.
Standard method for limiting peak power consumption.
Extended method for limiting peak power consumption.
Control function for fan operation during snowfall.
Overview and procedure for test operations.
Essential pre-power-on checks for test operations.
Procedure for setting unit addresses and system configuration.
Troubleshooting guide for issues encountered during test operations.
Procedure for checking the fan operation during test mode.
Procedure for checking cooling and heating operations during test mode.
Function to check the correct connection of refrigerant and control lines.
Function to start/stop indoor units from the outdoor unit.
Procedure for clearing errors from the system.
Function to distinguish connected remote controllers.
General overview of troubleshooting procedures and required tools.
Detailed troubleshooting methods based on check codes.
Troubleshooting based on error codes displayed on the remote controller.
Cross-reference of check codes across different displays and fault locations.
Important notes and guidelines for backup operation.
Procedure for setting up compressor backup operation.
Procedure for setting up outdoor unit backup operation.
Method for recovering refrigerant from a failed outdoor unit using pump-down.
Procedure for operating the system while a failed outdoor unit is under repair.
General outline for compressor replacement.
Detailed procedure for replacing compressors, including oil adjustment.
Procedures for exchanging PC boards.
Procedure for replacing indoor PC boards.
Procedures for replacing outdoor PC boards.
Information on concentration limits for R410A refrigerant and necessary safety measures.