SERVICE MANUAL
AIR-CONDITIONER (MULTI TYPE)
<SUPER MODULAR MULTI SYSTEM - i>
Outdoor Unit
Model name:
FILE NO. SVM-13024-2
MMY-MAP0804HT8(J)P
MMY-MAP1004HT8(J)P
MMY-MAP1204HT8(J)P
MMY-MAP1404HT8(J)P
MMY-MAP1604HT8(J)P
MMY-MAP0804HT8(J)P-E
MMY-MAP1004HT8(J)P-E
MMY-MAP1204HT8(J)P-E
MMY-MAP1404HT8(J)P-E
MMY-MAP1604HT8(J)P-E
MMY-MAP0804HT8(J)P-TR
MMY-MAP1004HT8(J)P-TR
MMY-MAP1204HT8(J)P-TR
MMY-MAP1404HT8(J)P-TR
MMY-MAP1604HT8(J)P-TR
<Heat Pump Model>
<4-way Cassette Type>
(MMU-AP***4HP-E) (Made in Thailand model) SVM-13-011
<2-way Cassette Type>
(MMU-AP
***
2WH) A10-007
<Concealed Duct Standard Type>
(MMD-AP
***
6BH-E) A12-005
<Slim Duct Type>
(MMD-AP0244SPH-E, AP0274SPH-E) A12-005
Fresh Air Intake Indoor Unit Type
(MMD-AP
****
HFE) A06-016
<Air to Air Heat Exchanger with DX Coil Unit Type>
(MMD-VN
*****
HEXE
*
) A10-022-2
High-wall Type
(MMK-AP
***
3H) (Made in Thailand model) SVM-09-059
Console Type
(MML-AP
****
NH-E) (Made in Thailand model) SVM-11-036
Other indoor units
(MM
*
-AP
*****
H
*
) A10-033
MMY-MAP0804HT7(J)P
MMY-MAP1004HT7(J)P
MMY-MAP1204HT7(J)P
MMY-MAP1404HT7(J)P
MMY-MAP1604HT7(J)P
MMY-MAP0804T8(J)P
MMY-MAP1004T8(J)P
MMY-MAP1204T8(J)P
MMY-MAP1404T8(J)P
MMY-MAP1604T8(J)P
MMY-MAP0804T8(J)P-T
MMY-MAP1004T8(J)P-T
MMY-MAP1204T8(J)P-T
MMY-MAP1404T8(J)P-T
MMY-MAP1604T8(J)P-T
MMY-MAP0804T8(J)P-SG
MMY-MAP1004T8(J)P-SG
MMY-MAP1204T8(J)P-SG
MMY-MAP1404T8(J)P-SG
MMY-MAP1604T8(J)P-SG
<Cooling Only Model>
MMY-MAP0804T8(J)P-ID
MMY-MAP1004T8(J)P-ID
MMY-MAP1204T8(J)P-ID
MMY-MAP1404T8(J)P-ID
MMY-MAP1604T8(J)P-ID
This service manual provides relevant explanations about new outdoor unit (SMMS-i).
Please refer to the following service manuals for each indoor units.

Table of Contents

Questions and Answers

  • E
    Elizabeth AguilarAug 8, 2025
    What to do if the Toshiba MMY-MAP0804T8P-T indoor remote controller is not accepted and a check code is displayed?
    • K
      kimberlyalexanderAug 8, 2025
      If the indoor remote controller isn't working and a check code appears on the interface PC board of the header unit, the issue might stem from unset addresses or incorrect power settings. Start by setting up the addresses for the line and indoor units. If you're using group control, make sure a group address is set up. Also, confirm that the indoor unit power is turned on, ensuring you power on the indoor units before the outdoor units. Finally, check that the indoor/outdoor communication line is correctly connected to the U1/U2 terminal of the header unit.
  • C
    chelseasanchezAug 17, 2025
    What to do if my Toshiba Air Conditioner is not accepting operation from the indoor remote controller?
    • S
      sherry82Aug 17, 2025
      If your Toshiba Air Conditioner indoor unit isn't responding to the remote controller and there's no check code on the header unit's interface PC board, the problem likely lies in the communication wiring or address settings. First, check the communication line between the indoor and outdoor units and modify the wiring if necessary. Next, ensure that both the line address and indoor address are correctly set for the unit that's not responding. If you are using indoor group control, make sure that the power of the header unit of the group is turned on. If the unit is under individual control, verify that the group address is set to “0”. Finally, confirm that the power is turned on for the unit and that the indoor remote controller is properly wired.
  • K
    Kevin DelgadoAug 28, 2025
    Why does my Toshiba MMY-MAP0804T8P-T Air Conditioner display a lower number of connected units after address setup?
    • B
      Brandon WilsonAug 28, 2025
      If you're encountering a situation where a lower number of connected units is displayed after address setup, it might be due to miswiring or unconnected wires in the communication lines. * For outdoor units, check the communication lines between them. If you find any issues, correct the wiring, set up the addresses again, and then verify the number of connected outdoor units. * Similarly, inspect the communication lines between indoor units. Correct any miswiring, set up the addresses again, and check the number of connected indoor units. Also, verify the wiring of the indoor remote controller.

Toshiba MMY-MAP0804T8P-T Specifications

General IconGeneral
Cooling Capacity8.0 kW
Heating Capacity9.0 kW
RefrigerantR410A
Sound Power Level Cooling62 dB
Sound Power Level Heating63 dB