SERVICE MANUAL
AIR-CONDITIONER (MULTI TYPE)
<SUPER HEAT RECOVERY MULTI-e>
Outdoor Unit
Model name:
FILE NO. SVM-16082-12
MMY-MAP0726FT2P-UL
Flow Selector Unit (FS unit)
Model name:
RBM-Y0383FUL RBM-Y0611F4PUL
RBM-Y0613FUL RBM-Y0611F6PUL
RBM-Y0963FUL
RBM-Y0384FUL
RBM-Y0614FUL
RBM-Y0964FUL
Revised on Jan, 2023

Table of Contents

Other manuals for Toshiba MMY-MAP0726FT2P-UL

Questions and Answers

  • S
    Sharon HarrisJul 25, 2025
    Why does my Toshiba MMY-MAP0726FT2P-UL display a check code when the outdoor power is off?
    • J
      Jonathan EnglishJul 25, 2025
      If a check code appears on your Toshiba Air Conditioner's remote controller, first, verify that the header outdoor unit power is on. If the outdoor power is off, this could be the cause. If the power of a follower unit is not turned on, turn on the power.
  • A
    Amanda MartinezJul 30, 2025
    What to do if my Toshiba MMY-MAP0726FT2P-UL displays a check code due to exceeding the number of connected units?
    • B
      banksbrentJul 30, 2025
      If a check code appears on your Toshiba Air Conditioner's remote controller, it could be due to exceeding the number or capacity of connected indoor units. In this case, adjust the number or capacity of connected indoor units.
  • S
    Sarah RossAug 3, 2025
    What to do if my Toshiba MMY-MAP0726FT2P-UL Air Conditioner displays a check code due to communication issues between indoor and FS units?
    • J
      jacquelinerobinsonAug 3, 2025
      If a check code appears on your Toshiba Air Conditioner's remote controller, it might be caused by communication trouble between indoor unit(s) and FS unit(s). To resolve this, check the order in which power was turned on and inspect the indoor unit(s)-FS unit(s) cable.
  • C
    Christine MartinAug 7, 2025
    What does it mean when my Toshiba MMY-MAP0726FT2P-UL Air Conditioner displays a check code related to FS unit installation?
    • L
      Leah BondAug 7, 2025
      If a check code appears on your Toshiba Air Conditioner's remote controller, it may be due to FS unit(s) installation trouble. Set up only Multi port type and single port type (Long piping model) FS unit(s) to 36 ton or more system. Also, check FS units address and indoor units operation mode priority setting.
  • N
    Nathan PittsAug 11, 2025
    How to check the terminator resistor on my Toshiba MMY-MAP0726FT2P-UL Air Conditioner if a check code is displayed?
    • D
      Donald RossAug 11, 2025
      If a check code appears on your Toshiba Air Conditioner's remote controller, it may be due to the absence of an outdoor terminator resistor or the presence of two or more terminator resistors. Check SW30 bit 2 of the header unit. No connection between multiple refrigerant lines: SW30 bit 2 is on. Connection between multiple refrigerant lines: SW30 bit 2 of the connected header unit is turned on only for one line.
  • B
    Brenda SmithAug 16, 2025
    What to do if a check code appears on my Toshiba MMY-MAP0726FT2P-UL Air Conditioner due to a PC board failure?
    • E
      Emily BensonAug 16, 2025
      If a check code appears on your Toshiba Air Conditioner's remote controller, it could be due to a transmission circuit trouble at the interface side (PC board failure). In this case, replace the interface PC board.
  • K
    Kelsey TaylorAug 20, 2025
    What should I do if my Toshiba MMY-MAP0726FT2P-UL Air Conditioner displays a check code after communication from all indoor units is interrupted?
    • W
      Wanda HillAug 20, 2025
      If a check code appears on your Toshiba Air Conditioner's remote controller, it could be due to communication from all the indoor units being interrupted after address setup. Check and correct disconnection of the indoor/ outdoor communication line (the communication line between the header unit and the leading indoor unit). Also, check for the influence of communication noise.

Summary

PRECAUTIONS FOR SAFETY

Refrigerant (R410 A)

Wiring Diagrams

2-1. Outdoor Unit

Wiring diagrams for the outdoor unit.

2-2. Single port FS unit (Flow Selector unit)

Wiring diagrams for single port FS units.

Parts Rating

Outdoor (Inverter) Print Circuit Board

Refrigerant Piping Systematic Drawing

Control Outline

Indoor Unit

Outline of control functions for indoor units.

Outdoor Unit

Outline of control functions for outdoor units.

Applied control for Outdoor Unit

Applied control for Outdoor Unit

Overview of applied controls for outdoor units.

Outdoor Fan High Static Pressure Shift

Adjusts outdoor fan speed for high static pressure duct installation.

Priority Operation Mode Setting

Sets priority for cooling or heating operation modes.

Applied Control of Outdoor Unit

Details optional controls for outdoor units via P.C. boards.

TEST OPERATION

Procedure and Summary of Test Operation

Outlines the steps for performing a test operation.

Check Items before Test Operation (before powering-on)

Lists essential checks before initiating test operation.

Check at Main Power-on

Checks to perform after main power is turned on.

Address Setup

Procedure for setting up unit addresses.

Address Setup and Check Procedure

Step-by-step guide for address setup and verification.

Address Setup Procedure

Detailed procedure for setting unit addresses.

Troubleshooting in Test Operation

Guidance for troubleshooting issues during test operation.

A Check Code is Displayed on the Remote Controller

Troubleshooting check codes displayed on the remote controller.

Test Operation Check

Checks to perform after test operation.

Service Support Function

Check code Clearing Function

Procedures for clearing check codes from the system.

Refrigerant leakage detection

Detects refrigerant leaks by comparing PMV opening.

TROUBLESHOOTING

Troubleshooting Method

Guides on using LCD displays for troubleshooting.

Troubleshooting Based on Information Displayed on Remote Controller

Troubleshooting based on remote controller display and history.

Diagnosis procedure for each check code

Flowcharts for diagnosing specific check codes.

BACKUP OPERATION (EMERGENCY OPERATION)

Compressor Backup Operation Setting

Setting up compressor backup operation.

Outdoor Unit Backup Operation Setting

Setting up outdoor unit backup operation.

OUTDOOR UNIT REFRIGERANT RECOVERY METHOD

Refrigerant Recovery from Failed Outdoor Unit (Pump-Down)

Method for recovering refrigerant from a failed outdoor unit via pump-down.

REPLACING COMPRESSORS

Check Procedure to Search Cause of Compressor Oil Shortage

Diagnosing the cause of compressor oil shortage.

OUTDOOR UNIT PARTS REPLACEMENT METHODS

P.C. BOARD EXCHANGE PROCEDURES

SINGLE PORT FS UNIT (LONG PIPING MODEL) PARTS REPLACEMENT METHOD

WARNINGS ON REFRIGERANT LEAKAGE

Check of Concentration Limit

Guidelines for ensuring refrigerant concentration limits are not exceeded.

Toshiba MMY-MAP0726FT2P-UL Specifications

General IconGeneral
BrandToshiba
ModelMMY-MAP0726FT2P-UL
CategoryAir Conditioner
LanguageEnglish