CAUTION
If any of the following conditions occur, turn off the main power supply switch and immediately contact the dealer:
Switch operation does not work properly.
The main power fuse often blows out, or the circuit breaker is often activated.
A foreign matter or water fall inside the air conditioner.
When the air conditioner does not operate even after the cause of the protective device activation has been
removed.
(The operation lamp and
on the remote controller are ashing. When and a combination of , , , , or
and a number are displayed on the remote controller, also inform a quali ed service person of the display
content.)
Any other unusual conditions are observed.
Procedure Description
1
When pushing and buttons at the same time for 4
seconds or more, the following display appears.
If [ Service check] is displayed, the mode enters in the error
log mode.
[01 : Order of error log] is displayed in CODE No. window.
[Check code] is displayed.
[Indoor unit address in which an error occurred] is displayed
in UNIT No..
2
Every pushing of [ / ] button used to set temperature, the error log stored in memory is
displayed in order.
The numbers in CODE No. indicate CODE No. [01] (latest) to [04] (oldest).
CAUTION
Do not push
button because all the error log of the indoor unit will be deleted.
3
After con rmation, push button to return to the usual display.
1. Check the errors according to the above procedure.
2. Ask an authorized dealer or quali ed service (maintenance) professional to repair or maintain the air conditioner.
3. More details of the check code are explained in Service Manual.
Con rmation and check
When an error occurred in the air conditioner, the check
code and the indoor unit No. appear on the display part
of the remote controller. The check code is only displayed
during the operation. If the display disappears, operate the
air conditioner according to the following “Con rmation of
error log” for con rmation.
Con rmation of error log
When an error occurred on the air conditioner, the error log
can be con rmed with the following procedure. (The error
log is stored in memory up to 4 errors.) The log can be
con rmed from both operating status and stop status.
12 Speci cations
Model
Sound power level (dBA)
Weight (kg)
Cooling Heating
MMY-MAP0806HT8P-E
MMY-MAP0806HT8JP-E
74 74 242
MMY-MAP1006HT8P-E
MMY-MAP1006HT8JP-E
74 74 242
MMY-MAP1206HT8P-E
MMY-MAP1206HT8JP-E
80 82 242
MMY-MAP1406HT8P-E
MMY-MAP1406HT8JP-E
80 82 300
MMY-MAP1606HT8P-E
MMY-MAP1606HT8JP-E
81 83 300
MMY-MAP1806HT8P-E
MMY-MAP1806HT8JP-E
81 83 371
MMY-MAP2006HT8P-E
MMY-MAP2006HT8JP-E
82 84 371
MMY-MAP2206HT8P-E
MMY-MAP2206HT8JP-E
83 84 371
MMY-MAP0806T8P-E
MMY-MAP0806T8JP-E
74 - 241
MMY-MAP1006T8P-E
MMY-MAP1006T8JP-E
74 - 241
MMY-MAP1206T8P-E
MMY-MAP1206T8JP-E
80 - 241
MMY-MAP1406T8P-E
MMY-MAP1406T8JP-E
80 - 299
MMY-MAP1606T8P-E
MMY-MAP1606T8JP-E
81 - 299
MMY-MAP1806T8P-E
MMY-MAP1806T8JP-E
81 - 370
MMY-MAP2006T8P-E
MMY-MAP2006T8JP-E
82 - 370
MMY-MAP2206T8P-E
MMY-MAP2206T8JP-E
83 - 370
Check code Indoor unit No. in which
an error occurred
– 22 –
43-EN 44-EN