6-1. Indoor Unit
6-2. Outdoor Unit
No. Parts name Type Specifications
SJM-240-25
AC 220~240V, 25W
2 Room temp. sensor (TA-sensor) ( - ) 10k at 25°C
3 Heat exchanger temp. sensor (TC-sensor) ( - ) 10k at 25°C
4 Louver motor
24BYJ48A-080
Output (Rated) 4 phase, DC12V
1
Fan motor
(for indoor)
6. SPECIFICATIONS OF ELECTRICAL PARTS
No. Type name Specifications
1 Compressor
ASK89D53UEZ
3-Phases (6-Poles) ; 682W
2 Fan Motor
ICF-140-43-4R
DC 140-340V, 43W
3 Pulse Modulating Valve (PMV) coil PQ-M10012-000313 DC 12V
4 4-Way Valve coil DXQ-939 AC 220-240V
5 Suction temp. sensor (TS sensor) (Inverter attached)
6 Discharge temp. sensor (TD sensor) (Inverter attached)
7 Outside air temp. sensor (TO sensor) (Inverter attached)
8 Heat Exchanger temp. sensor (TE sensor) (Inverter attached)
9 Terminal block (5 poles) JXO-5B AC 250V, 20A
Parts name
10k at 25°C
10k at 25°C
10k at 25°C
62k at 20°C
FILE NO. SVM-17030
- 18 -