EasyManua.ls Logo

Toshiba RAS-10G2KVP-E - Electrical Parts Specifications

Toshiba RAS-10G2KVP-E
127 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
6-2. Outdoor Unit
No.
1 Reactor L = 10mH, 16A
2 Outdoor fan motor DC140V, 43W
3 Suction temp. sensor (TS sensor)
10k
(25°C)
4 Discharge temp. sensor (TD sensor)
62k
(20°C)
5 Outside air temp. sensor (TO sensor)
10k
(25°C)
6 Heat exchanger temp. sensor (TE sensor)
10k
(25°C)
7 Terminal block (6P) 20A, AC250V
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
Parts name Model name Rating
ICF-140-43-4R
No.
Fan motor (for indoor)
2 Room temp. sensor (TA-sensor)
10k
at 25°C
3 Heat exchanger temp. sensor (TC-sensor)
10k at 25°C
4
Louver motor
Output (Rated) 1W, 16 poles, DC12V
( - )
(
-
)
24BYJ48-HT
MF-340-30-3 DC250~370, 30W
Parts name
1
Specif icationsType
5
Heat exchanger temp. sensor (Tcj-sensor)
10k at 25°C
(
-
)
FILE NO. SVM-14017
CH-57-Z-T ; R
JX0-6B
DA150A1T-21F
3-phases 4-poles 1100W
10k
13k, 16k
DC12V
9 Coil for PMV DC12V
10 Coil for 4-way valve
CAM-MD12TCTH-5
STF-H01AZ1724A1
Compressor
3-phases 4-poles 750W
8
DA111A1F-24F

Table of Contents