– 29 –
Item
2. Indoor fan
motor control
Operation flow and applicable data, etc.
<In cooling operation>
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respec-
tively. (Table 1)
Description
* Symbols
UH : Ultra High
H : High
M+ : Medium+
M : Medium
L+ : Low+
L: Low
L- : Low–
UL : Ultra Low
SUL : Super Ultra Low
* The values of fan speed and air flow
volume indicate on the table are
measured when the louver is inclined
downward. Fan speed and air flow
volume broadly vary with position
(Fig. 1)
(Fig. 2)
+2.5
Ta
[
°C
]
+2.0
+1.5
+1.0
+0.5
Tsc
a
b
c
d
e
M+(WC)
*3
*4
*5
L(W7)
Air volume AUTO
L
L+
M
M+
H
W7
(L + M) / 2
WA
(M + H) / 2
WD
Indication
Fan speed
Fan speed setup
COOL ON
AUTO
MANUAL
*3 : Fan speed = (M + –L) x 3/4 + L
*4 : Fan speed = (M + –L) x 2/4 + L
*5 : Fan speed = (M + –L) x 1/4 + L
(Linear approximation
from M+ and L)
FILE NO. SVM-14017
(Table 1) Indoor fan air flow rate
Quiet
W5
of louver.
1) When setting the fan speed to L,
L+, M, M+,H or Quiet on the
remote controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture, room temperature, and heat
exchanger temperature.
RAS-10G2KVP-E RAS-13G2KVP-E RAS-16G2KVP-E
Cooling Heating Cooling Heating Cooling Heating
Fan speed Air Flow rate Fan speed Air Flow rate Fan speed Air Flow rate Fan speed Air Flow rate Fan speed Air Flow rate Fan speed Air Flow rate
(rpm)
(m
3
/h)
(rpm)
(m
3
/h)
(rpm)
(m
3
/h)
(rpm)
(m
3
/h)
(rpm)
(m
3
/h)
(rpm)
(m
3
/h)
WF
UH UH/H
1060 661 1080 676 1100 690 1140 731 1120 713 1160 746
WE
UH H
1060 661 1080 676 1100 698 1140 731 1120 713 1160 746
WD
H M+ UH
1040 647 930 551 1080 676 990 611 1100 690 1010 621
WC
M+ M+ H
900 527 930 551 930 551 990 611 950 567 1010 621
WB
M M+
900 527 780 423 930 551 840 475 950 567 860 493
WA
M M/L+ M
760 409 780 423 780 423 840 475 800 442 860 493
W9
L+
760 409 710 368 780 423 750 401 800 442 770 416
W8
L+ L L+
690 349 640 305 710 368 660 322 730 384 680 338
W7
L L- L
620 287 560 243 640 305 600 274 660 322 620 287
W6
L- L
520 205 560 243 560 243 600 274 580 255 620 287
W5
UL UL L- L-
500 187 540 224 540 224 580 255 560 243 600 274
W4
UL
480 173 500 187 520 205 560 243 540 224 580 255
W3
SUL UL
SUL/SL-
460 155 480 173 500 187 540 224 520 205 560 243
W2
SUL SL
450 147 460 155 480 173 520 205 500 187 540 224
W1
SL-
440 142 440 142 440 142 440 142 440 142 440 142
Fan speed
Cool Heat PAP Dry
Level