1. Operation control
Description
Receiving the users operation condition setup, the operation statuses of indoor/outdoor units are
controlled.
1) The operation conditions are selected by the remote controller as shown in the below.
2) A signal is sent by ON button of the remote controller.
3)
The signal is received by a sensor of the indoor unit and processed by the indoor controllers as
shown in the below. The power relay is tumed ON and power supply to the outdoor unit.
4) The indoor controller controls the indoor fan motor and louver motor.
5) The indoor controller sends the operation command to the outdoor controller, and sends/receives
the control status with a serial signal.
6)
The outdoor controller controls the operation as shown in the below, and also controls the
compres-sor, outdoor fan motor, 4-way valve and pulse Modulating valve are controlled
Remote controller
Control contents of remote controller
ON/OFF (Air conditioner/Air purifier)
Operation select (COOL/HEAT/AUTO/DRY)
Temperature setup
Air direction
Swing
Air volume select (AUTO/QUIET/LOW/LOW+/MED/MED+/HIGH)
ECO
ON timer setup
OFF timer setup
Hi-POWER
Selection of operation
conditions
ON/OFF
COMFORT SLEEP
QUIET
PRESET
ONE-TOUCH
FILE NO. SVM-14017
POWER-SELECTION
Indoor unit control
Operation command
Power relay
signal Serial
transmission
signalSerial
Inverter
Transmission
Signal
receiving
Outdoor unit
Indoor unit control
Command signal generating function for
indoor unit operation
Calculation function (temperature
calculation)
3 minute delay function for compressor
reactivation
Activation compensation function for indoor
fan
Cold draft preventive function
Timer function
Indoor heat exchanger release control
Outdoor unit control
Inverter output frequency
control
Waveform composite function
Calculation function
(temperature calculation)
AD conversion function
Quick heating function
Compressor reactivation delay
function
Current release function
GTr overload protective function
Defrost operation function
Outdoor temperature estimation
Indoor fan motor
Louver motor
Compressor
Outdoor fan motor
Four-way valve
Pulse modulating valve
Indoor unit
A/B Selection function
Contront air flow (wide angle/Right wide/Left wide/spot front/spot right/spot lift)