10-3. Indoor Unit
10-3-1. Installation Place
A place which provides the spaces around the
indoor unit as shown in the diagram.
A place where there are no obstacle near the air
inlet and outlet.
A place which allows easy installation of the piping
to the outdoor unit.
A place which allows the front panel to be opened.
The indoor unit shall be installed as top of the
indoor unit comes to at least 2 m height.
Also, it must be avoided to put anything on the top
of the indoor unit.
CAUTION
Direct sunlight on the indoor unit wireless
receiver should be avoided.
The microprocessor in the indoor unit should
not be too close to RF noise sources.
(For details, see the owner's manual.)
Remote control
A place where here are no obstacles such as a
curtain that may block the signal from the indoor unit
Do not install the remote control in a place exposed
to direct sunlight or close to a heating source such
as a stove.
Keep the remote control at least 1 m apart from
the nearest TV set or stereo equipment.
(This is necessary to prevent image disturbances or
noise interference.)
The location of the remote control should be
determined as shown below.
10-3-2. Cutting a Hole and Mounting
Installation Plate
Cutting a hole
When installing the refrigerant pipes from the rear.
1. After determining the pipe hole position on the
installation plate (
ð
) drill the pipe hole (Ø65
mm) at a slight downward slant to the outdoor
side.
NOTE :
When drilling into a wall that contains a metal lath,
wire lath or metal plate, be sure to use a pipe hole
brim ring sold separately.
Mounting the installation plate
Fig. 10-3-3
Fig. 10-3-2
FILE NO. SVM-14017
Fig. 10-3-1
The center of the pipe hole
is above the arrow.
35
Ø
65
45º
45º
75º
(Side view) (Top view)
Indoor unit
Reception range
Remote
control
Remote
control
Reception
range
Indoor unit
5
Anchor bolt holes
Hook
Hook
Hook
Pipe hole
Pipe hole
Installation
plate
Mounting screw
Weight
Indoor unit
Thread
2 m or more from oor
52
40
190
104
225
137
1