8. Louver control
1) Louver
position
Operation flow and applicable data, etc.
This function controls the air direction of the indoor unit.
Description
The position is automatically controlled according to the operation
The set louver position is stored in memory by the microcomputer,
The angle of the louver is indicated as the louver closes fully is 0°.
mode (COOL/HEAT).
and the louver returns to the stored position when the next operation
is performed. (Cooling/Heating memory position)
36
FILE NO. SVM-14017
1) Louver position in cooling operation
Manual and automatic operation HI-POWER operation
Initial setting is directs downward (13.4°) Default setting is directs downward (26.1°)
Wide air direction
Wide position is directs downward (13.4°)
Wide-angle Right wide Left wide
Left side lover setting is left facing (45.9°)
Right side lover setting is right facing (45.9°)
Left side lover setting is front facing (0°)
Right side lover setting is right facing (45.9°)
Left side lover setting is left facing (45.9°)
Right side lover setting is front facing (0°)
Spot air direction
Spot position is directs downward (43.1°)
Wide front Sport right Spot left
Left side lover setting is front facing (0°)
Right side lover setting is front facing (0°)
Left side lover setting is right facing (45.9°)
Right side lover setting is right facing (45.9°)
Left side lover setting is left facing (45.9°)
Right side lover setting is left facing (45.9°)