Item
8. Louver control
1) Louver
position
Operation flow and applicable data, etc.
This function controls the air direction of the indoor unit.
Description
• The position is automatically controlled according to the operation
• The set louver position is stored in memory by the microcomputer,
The angle of the louver is indicated as the louver closes fully is 0°.
mode (COOL/HEAT).
and the louver returns to the stored position when the next operation
is performed. (Cooling/Heating memory position)
– 36 –
FILE NO. SVM-14017
1) Louver position in cooling operation
Manual and automatic operation HI-POWER operation
Initial setting is directs downward (13.4°) Default setting is directs downward (26.1°)
Wide air direction
Wide position is directs downward (13.4°)
Wide-angle Right wide Left wide
Left side lover setting is left facing (45.9°)
Right side lover setting is right facing (45.9°)
Left side lover setting is front facing (0°)
Right side lover setting is right facing (45.9°)
Left side lover setting is left facing (45.9°)
Right side lover setting is front facing (0°)
Spot air direction
Spot position is directs downward (43.1°)
Wide front Sport right Spot left
Left side lover setting is front facing (0°)
Right side lover setting is front facing (0°)
Left side lover setting is right facing (45.9°)
Right side lover setting is right facing (45.9°)
Left side lover setting is left facing (45.9°)
Right side lover setting is left facing (45.9°)