Item
8. Louver control
Operation flow and applicable data, etc. Description
– 37 –
FILE NO. SVM-14017
2) Louver position in heating operation
Manual and automatic operation HI-POWER operation
Initial setting is directs downward (43.1°) Default setting is directs downward (26.1°)
Wide air direction
Wide position is directs downward (43.1°)
Wide-angle Right wide Left wide
Left side lover setting is left facing (45.9°)
Right side lover setting is right facing (45.9°)
Left side lover setting is front facing (0°)
Right side lover setting is right facing (45.9°)
Left side lover setting is left facing (45.9°)
Right side lover setting is front facing (0°)
Spot air direction
Spot position is directs downward (43.1°)
Wide front Sport right Spot left
Left side lover setting is front facing (0°)
Right side lover setting is front facing (0°)
Left side lover setting is right facing (45.9°)
Right side lover setting is right facing (45.9°)
Left side lover setting is left facing (45.9°)
Right side lover setting is left facing (45.9°)