– 3 –
FILE NO. SVM-02003
RAS-13UKPX-T2 RAS-10UKPX-T2 RAS-07UKPX-T2
RAS-13UKX / RAS-13UAX RAS-10UKX / RAS-10UASX
RAS-13UAX-T2 RAS-10UAX-T2 RAS-07UAX-T2
ITEM Cooling
Capacity
220V 220V 220V 220V 240V 220V 240V
kW 3.65 2.70 2.10 3.70 3.75 2.60 2.60
Phase 1∅
Power source V 220 220 – 240
Hz 50
Power consumption kW 1.05 0.80 0.60 1.25 1.29 0.88 0.93
Power factor % 98 96 92 98 95 95 94
Running Indoor A 0.15
current Outdoor A 4.70 3.65 2.80 5.66 5.53 4.05 3.98
Starting current A 25 11 24 16
Moisture removal lit/h 2.0 1.2 0.8 2.0 1.2
Noise Indoor (H/M/L) dB 41/35/31 39/33/26 38/32/26 41/35/31 39/33/26
Outdoor (220-240V) dB 49 46 44 47-48 45-46
Refrigerant
Name of refrigerant R-22
Rated amount kg 0.80 0.85 0.57 0.78 0.65
Refrigerant control Capillary tube
Gas side size mm ∅12.70 ∅9.52 ∅12.70 ∅9.52
Connection type Flare connection
Liquid side size mm ∅6.35
Interconnection
Connection type Flare connection
pipe
Maximum length
m 15*
1
10*
1
15*
1
10*
1
(One way)
Maximum height
m6 5 6 5
difference
INDOOR
RAS-13UKPX-T2 RAS-10UKPX-T2 RAS-07UKPX-T2 RAS-13UKX RAS-10UKX
Height mm 275
Dimensions Width mm 790
Depth mm 208
Net weight kg 10
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m
3
/h 630 570 630
Air volume Medium fan m
3
/h 550 490 460 550 490
Low fan m
3
/h 460 370 340 460 370
Fan motor output W 30
Air filter Honeycomb woven filter with PP frame
OUTDOOR
RAS-13UAX-T2 RAS-10UAX-T2 RAS-07UAX-T2 RAS-13UAX RAS-10UASX
Height mm 538 530 538 530
Dimensions Width mm 780 770 660 780 660
Depth mm 300 200 240 300 240
Net weight kg 41 30 26 37 28
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m
3
/h 1830 1700 1280 1700 1900 1420 1520
Fan motor output W 42 30 20 30
Compressor
Model
RM5515FNE96 RM5510GNE94 PH80T1-4C PH160T2-4L2 PH102T1-4C
Output W 1100 750 605 1100 750
Safety device Fuse, Overload relay
Louver type Automatic louver
Usable outdoor temperature range °C 21 ~ 43
1. SPECIFICATIONS
MODEL