6-1. Indoor Unit
6-2. Outdoor Unit
6. SPECIFICATIONS OF ELECTRICAL PARTS
No. ype SpecificatType
1
Fan Motor (for indoor)
2 Room temp. sensor (TA-sensor) (-) 10kΩ at 25°C
3 Heat exchanger temp. sensor (TC-sensor) (-) 10kΩ at 25°C
4
Louver motor (Horizontal) x 1 pcs.
24BYJ48A-080 Output (Rated) 4 phase, DC12V
Parts name
No. Type name Specifications
1 Compressor
RAS-18, 22 KTN130D30UFZ
3-Phases (6-Poles) ; 630W
RAS-24
DX151A1T-30N
3-Phases (6-Poles) ; 840W
2 Fan Motor
WDF-340-A43-1 DC 140-340V ; 43W
3 Pulse Modulating Valve (PMV) coil PQ-M10012-000313 DC 12V
4 4-Way valve coil
SQ-A2522G-000352
AC 220-240V
5 Reactor
RAS-18,22 CH-69-Z-T
L = 19mH, 10A
6 Suction temp. sensor (TS sensor) (Inverter attached)
10kΩ at 25°C
7 Discharge temp. sensor (TD sensor) (Inverter attached)
62kΩ at 20°C
8 Outside air temp. sensor (TO sensor) (Inverter attached)
9 Heat Exchanger temp. sensor (TE sensor) (Inverter attached)
10kΩ at 25°C
10 Terminal block
RAS-18,22(5 poles)
JXO-5B
AC 250V, 20A
Parts name
10kΩ at 25°C
ICF-340-30-6
DC-340V, 30W
MSBPC20F04
Output (Rated) 4 phase, DC12V
RAS-18,22
ICF-340-A70-1 DC 140-340V ; 70W
RAS-24
RAS-18,22
SQ-D27012-000752
DC 12V
RAS-24
RAS-24 CH-47-Z-T L = 7.6~8.4mH, 16A
RAS-24(6 poles)
JXO-6B
AC 600V, 30A
Louver motor (Vertical) x 2 pcs.