Unit model Indoor
RAS-24PKVSG-E
Outdoor
RAS-24PAVSG-E
Cooling capacity (kW)
Cooling capacity range (kW)
Heating capacity (kW)
Heating capacity range (kW)
Power supply
1Ph/50Hz/220-240V
Electric Indoor Operation mode Cooling
characteristic Running current (A) 0.38-0.35
Power consumption (W) 43
Power factor (%) 51
Outdoor Operation mode Cooling
Running current (A) 10.12-9.35
Power consumption (W) 2207
Power factor (%) 99
Starting current (A)
COP (Cooling / Heating) 3.11/3.32
Operating Indoor High (Cooling / Heating) (dB-A) 47/48
noise Medium (Cooling / Heating) (dB-A) 41/41
Low (Cooling / Heating) (dB-A) 35/35
Outdoor (Cooling / Heating) (dB-A) 53/53
Indoor unit Unit model
RAS-24PKVSG-E
Dimension Height (mm) 320
Width (mm) 1050
Depth (mm) 250
Net weight (kg) 14
Fan motor output (W) 30
Air flow rate (Cooling / Heating)
(m
3
/ min)
17.9/18.8
Outdoor unit Unit model
RAS-24PAVSG-E
Dimension Height (mm) 630
Width (mm) 800
Depth (mm) 300
Net weight (kg) 41
Compressor Motor output (W) 1100
Type
Model DX151A1T-30N
Fan motor output (W) 70
Air flow rate (Cooling / Heating)
(m
3
/ min)
48.6/48.6
Piping Type Flare connection
connection Indoor unit Liquid side (mm)
6.35
Gas side (mm)
12.70
Outdoor unit Liquid side (mm)
6.35
Gas side (mm)
12.70
Maximum length (m) 25
Maximum charge-less length (m) 15
Maximum height difference (m) 15
Refrigerant Name of refrigerant R32
Weight (kg) 1.14
Wiring Power supply 3 Wires: Includes earth (Outdoor)
connection Interconnection 4 Wires: Includes earth
Usable temperature range Indoor (Cooling / Heating)
(
o
C)
21-32/0-28
Outdoor (Cooling / Heating)
(C)
-15,46/-15,24
1.60-8.80
1.50-7.70
8.00
7.00
10.10
2-2. Specification
Twin rotary type with DC-inverter variable speed control
* The specification may be subject to change without notice for purpose of improvement.
Accessory Indoor unit
Installation plate
1
Wireless remote controller
1
Batteries 2
Remote controller holder
1
Toshiba IAQ filter
2
Mounting screw
6(4x25L)
Remote controller holder
Flat head wood screw
Installation manual 1
Owner's manual
1
2(3.1Lx16L)
Heating
0.38-0.35
43
51
Heating
10.92-9.95
2367
99
10.80