FILE NO. SVM-06020
4-5. Outdoor Unit (RAS-24GA-ES2)
No. Parts name Type Specifications
Output (Rated) 2200W, 2poles, 1 phase, 220 240V, 50Hz
1 Compressor PA290X3CS-4MU1 Winding resistance ( ) Red-Black White-Black
(at 20°C) 1.13 2.10
Output (Rated) 42W, 4poles, 1 phase, 220 240V, 50Hz
2 Fan motor (for outdoor) FG-240-42A Winding resistance () Red-Black White-Black
(at 20° C) 128 126
3
Running capacitor
451305L AC 450V, 3.0µ F
(for fan motor)
4
Running capacitor
RS44B506U0218S
AC 440V, 50µ F
(for compressor)
5
Magnetic contactor
CLK-35J
220 240V, 50Hz
4-6. Outdoor Unit (RAS-18GA-ES2)
No. Parts name Type Specifications
Output (Rated) 1500W, 2poles, 1 phase, 220 240V, 50Hz
1 Compressor PA225X2CS-4KU1 Winding resistance () Red-Black White-Black
(at 20°C ) 1.54 2.48
Output (Rated) 42W, 6poles, 1 phase, 220 240V, 50Hz
2 Fan motor (for outdoor) WLF-240-42A-1 Winding resistance () Red-Black White-Black
(at 20°C) 188 289
3
Running capacitor
451205L AC 450V, 2.0µF
(for fan motor)
4
Running capacitor
RS44B506U0218S AC 440V, 50µF
(for compressor)
5
Magnetic contactor
CLK-26J
220 240V, 50Hz
- 14 -

Table of Contents