7. OPERATION DESCRIPTION
7-1-1. Louver contr
ol
(1) Vertical air flow louver
Position of veritcal air flow louver is automatically
controlled according to the operation mode.
Besides, position of vertical air flow louver can be
arbitrarily set by pressing [FIX] button.
The louver position which is set by [FIX] button is
stored in the microcomputer, and the louver is
automatically set at the stored position for the next
operation.
(2) Swing
If [SWING] button is pressed when the indoor unit
is in operation, the vertical air flow louver starts
swinging. When [FIX] button is pressed, it stops
swinging.
7-1-2. Indoor fan control (AC Fan motor)
(1) The indoor fan is operated by the stepless speed
change AC motor
.
(2) For air flow level, speed of the indoor fan motor is
controlled in five steps (LOW, LOW
+
, MED, MED
+
and HIGH). If AUTO mode is selected, the fan
motor speed is automatically controlled by the
difference between the preset temperature and
the room temperature.
7-1.Outline of Air Conditioner Control
This is a fixed capacity type air conditioner, which uses
a AC motor for an indoor fan. The AC motor drive
circuit is mounted in the indoor unit. And electrical
parts which operate the compressor and the outdoor
fan motor, are mounted in the outdoor unit.
The air conditioner is mainly controlled by the indoor
unit controller. The controller operates the indoor fan
motor based upon commands transmitted by the
remote control and transfers the operation commands
to the outdoor unit controller.
The outdoor unit controller receives operation
commands from the indoor unit, and operates the
outdoor fan motor and the compressor.
(1) Role of indoor unit controller
The indoor unit controller receives the operation
commands from the remote control and executes
them.
· Temperature measurement at the air inlet of the
indoor heat exchanger by the indoor
temperature sensor
· Temperature setting of the indoor heat
exchanger by the heat exchanger sensor
· Louver motor control
· Indoor fan motor operation control
· LED display control
· T ransferring of operation commands to the
outdoor unit
· Receiving of information of the operation status
and judging of the information or indication of
error
(2) Role of outdoor unit controller
The outdoor unit controller receives the operation
commands from the indoor controller and
executes them.
· Compressor operation
control
· Operation control of
outdoor fan motorf
·
when the outdoor unit receives the shutdown
command
· Defrost control in heating operation
(Temperature measurement by the outdoor heat
exchanger and control for the four-way valve
and the outdoor fan motor) *Heat pump Model
only
Turning off the compressor and outdoor fan
Operations according
to the commands
from the indoor unit
Cooling
OPERATION
Fan Only
Dry
MODE
1300
RAS-24GKHP Series
Model
RAS-18GKH Series
FAN TAP
RAS-24GKP Series
RAS-18GKP Series
Heat
rpm
Air Flow volume(m /h)
3
rpm
Air Flow volume(m /h)
3
rpm
Air Flow volume(m /h)
3
rpm
Air Flow volume(m /h)
3
UH H
M+
M L+
L L- UL SUL/SL-
SUL/SL-
UL
L-LL+
MUH H
H M+ M
L+
L L-
UL SUL
M+ M
900
900
13001300
900
1300
900
1300
900
1250 1200
1150 1050 1000 900 800 700
600
380
300
L+
L L-
600
500
300
220
700
380
600
300
461
700
380
800
461
700
380
543
800
461
900
543
800
461
625
900
543
1000
625
900
543
667
950
584
1050
667
950
584
750
1050
667
1150
750
1050
667
790
1150
750
1250
830
1150
750
830
Note : Under some function of setting. The fan motor is controlled automatically.
Then LOW
+
= LOW + MED and MED
+
= MED + HIGH
2
Table 7-1-1
2
1100
708
- 20 -