6-1. Indoor Unit
6-2. Outdoor Unit
6. SPECIFICATIONS OF ELECTRICAL PARTS
No. Type name Specifications
1 Compressor
RAS-18, 22
KTN130D30UFZ 3-Phases (6-Poles) ; 1075W
DX151A1T-30N 3-Phases (4-Poles) ; 1170W
2 Fan Motor
WDF-340-A43-1 DC 140-340V ; 43W
3 Pulse Modulating Valve (PMV) coil PQ-M10012-000313 DC 12V
4 4-Way valve coil
5 Reactor CH-69-Z-T L = 19mH, 10A
6 Suction temp. sensor (TS sensor) (Inverter attached)
10kΩ at 25°C
7 Discharge temp. sensor (TD sensor) (Inverter attached)
62kΩ at 20°C
8 Outside air temp. sensor (TO sensor) (Inverter attached)
9 Heat Exchanger temp. sensor (TE sensor) (Inverter attached)
10kΩ at 25°C
10 Terminal block JXO-5B
AC 250V, 20A
Parts name
10kΩ at 25°C
SQ-A2522G-000352
AC 220-240V
No. Typeype Specificat
1
Fan Motor (for indoor)
2 Room temp. sensor (TA-sensor) (-) 10kΩ at 25°C
3 Heat exchanger temp. sensor (TC-sensor) (-) 10kΩ at 25°C
5
Louver motor 24BYJ48-ST
Output (Rated) 4 phase, DC12V
Parts name
DRM-340-30-2
DC280-340V, 42W
4
Heat exchanger temp. sensor (TCJ-sensor)
10kΩ at 25°C
(-)
RAS-24
RAS-18, 22
RAS-24
ICF-340-A70-1 DC 140-340V ; 70W
RAS-18, 22
RAS-24
CH-57-Z-T L = 8.88 ~ 10.01mH, 18.5A