2-3. Operation Characteristic Curve
<Cooling> <Heating>
2-4. Capacity Variation ratio According to Temperature.
<Cooling>
<Heating>
0
2
4
6
8
10
12
0 10 20 30 40 50 60 70 80 90 10 0 110
Current (A)
Compressor Speed (RPS)
0
2
4
6
8
10
12
0 10 20 30 40 50 60 70 80 90 100 110
Current (A)
Compressor Speed (RPS)
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Outdoor : DB 35
o
C/WB 24
o
C
Indoor Air Flow : High
Pipe Length : 7.5 m
Voltage :
230V/ 50Hz
Conditions
Indoor : DB 20
o
C/WB 15
o
C
Outdoor : DB 7
o
C/WB 6
o
C
Indoor Air Flow : High
Pipe Length : 7.5 m
Voltage : 230V / 50Hz
RAS-B24N4KVSG-E
RAS-18N4KVSG-E
RAS-B22N4KVSG-E
RAS-B24N4KVSG-E
RAS-18N4KVSG-E
RAS-B22N4KVSG-E
Heating Capacity ratio (%)
120
100
80
60
40
20
0
-15 -10
-5 0
Outside Temperature ( ºC)
5 10
Capacity ratio : 100 %=
6.00kW(RAS-18N4KVSG-E)
7.00kW(RAS-B22N4KVSG-E)
8.00kW(RAS-B24N4KVSG-E)
Conditions
Indoor : DB 20
o
C/WB 15
o
C
Outdoor : DB 7
o
C/WB 6
o
C
Indoor Air Flow : High
Pipe Length : 7.5m
Voltage : 230V / 50Hz
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
Cooling Capacity ratio (%)
Outside Temperature (
o
C)
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Outdoor : DB 35
o
C/WB 24
o
C
Indoor Air Flow : High
Pipe Length : 7.5m
Voltage : 230V / 50Hz
Capacity ratio : 100 %=
5.00kW(RAS-18N4KVSG-E)
6.10kW(RAS-B22N4KVSG-E)
7.00kW(RAS-B24N4KVSG-E)
RAS-18N4KVSG-E
RAS-B22N4KVSG-E
RAS-B24N4KVSG-E