– 37 –
Initial setting of “Cooling storage position”
Louver : Horizontal blowing (37.4°)
Initial setting of “Heating storage position”
Louver : Directs downward (76.9°)
Heating operation/
AUTO (HEAT)
Cooling operation/
AUTO (COOL)
Air direction
Inclined
blowing
Blowing
downward
Inclined
blowing
Horizontal
blowing
Horizontal
blowing
Item
11. Louver control
1) Louver
position
2) Air direction adjustment
Operation flow and applicable data, etc.
This function controls the air direction of the indoor unit.
• The position is automatically controlled according to the operation
mode (COOL/HEAT).
• The set louver position is stored in memory by the microcomputer,
and the louver returns to the stored position when the next operation
is performed. (Cooling/heating memory position)
The angle of the louver is indicated as the horizontal angle is 0°.
1) Louver position in cooling operation
2) Louver position in heating operation
Description
• The louver position can
be arbitrarily set up by
pushing [FIX] button.
FILE NO. SVM-13004
• Swing operation is perform in range 35° with the Fixed position as
the center.
• If the swing range exceeded either upper or lower limit position,
swing operation is perfomed in range 35° from the limit.
3) Swing
• Swing
When pressing
Fixed
Position
before start
swing
Upper Limit
Position.
Lower Limit
Position
30
o
5
o
Swing
range 35
o
[SWING] button during
operation, the louver
starts swinging.
Upper Limit
Position.
Lower Limit
Position.
Fixed Position
before start
swing.
17.5
o
17.5
o
Swing
range 35
o